Proudly serving all of Florida with offices in Tampa, Orlando, and Fort Myers

Vibro Stone Columns: Self Storage Building, Tampa, FL

i 3 Table of Contents

Concrete Leveling Without Demolition Made Easy and Affordable

Uneven concrete isn’t just frustrating—it can quickly become a safety hazard or affect your property’s value. Whether it’s a sinking driveway or a sloping patio, the idea of tearing everything out and starting from scratch can feel overwhelming. The good news? You...

How Do Hurricanes Affect Foundations in Florida?

Introduction Florida’s long coastline and low-lying terrain make it one of the most hurricane-vulnerable places in the U.S. When storms strike, they don’t just damage roofs and siding — they often compromise the very ground beneath our homes. Recent storms have shown...

Can Foundation Cracks Cause Roof Issues? What Homeowners Should Know

You might not expect a problem with your foundation to show up on your roof, but it absolutely can. When your home’s foundation shifts, it sends stress all the way up through the walls and into your roof structure. What starts as a crack in your concrete slab could...

Sloped Floors Repair Solutions Made Easy for Every Homeowner

Noticed your floors are sloping or feeling uneven? That’s often a sign your home’s foundation may need attention. Sloped floors aren't just a cosmetic issue, they usually point to deeper structural concerns. And acting early can make all the difference. At Helicon, we...

Sinking Pool Deck Solution Made Easy for Your Home

Noticing cracks or uneven spots around your pool deck? It’s not just an eyesore; it can be unsafe for your family and guests. A sinking pool deck often signals shifting soil underneath; the sooner it’s fixed, the better. The good news? You don’t need to tear it all...

Long-term Soil Strengthening Method for Lasting Garden Health

Ever noticed cracks in your garden paths or uneven patches around your landscape? That might not just be wear and tear — it could be your soil quietly losing its strength. And once that happens, it doesn’t just affect your plants. It can put your entire property at...

Contact us anytime!

[cs_content][cs_element_section _id=”1″ ][cs_element_row _id=”2″ ][cs_element_column _id=”3″ ][cs_element_headline _id=”4″ ][cs_content_seo]Gandy Self Storage\n\n[/cs_content_seo][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”5″ ][cs_element_row _id=”6″ ][cs_element_column _id=”7″ ][cs_element_video _id=”8″ ][cs_element_gap _id=”9″ ][/cs_element_column][cs_element_column _id=”10″ ][cs_element_headline _id=”11″ ][cs_content_seo]Tampa, FL\n\n[/cs_content_seo][cs_element_gap _id=”12″ ][cs_element_text _id=”13″ ][cs_content_seo]CLIENT: Plaza Construction
ENGINEER: ECS Florida
MARKET: Retail
SOLUTION: Ground Improvement
SERVICES: Compaction Grout,Vibro \n\n[/cs_content_seo][cs_element_gap _id=”14″ ][cs_element_headline _id=”15″ ][cs_content_seo]Ground improvement for a 5-story, storage facility\n\n[/cs_content_seo][cs_element_headline _id=”16″ ][cs_content_seo]21 Compaction Grout Injection Points\n\n[/cs_content_seo][cs_element_headline _id=”17″ ][cs_content_seo]220 Vibro-Replacement Stone Columns\n\n[/cs_content_seo][cs_element_gap _id=”18″ ][cs_element_button _id=”19″ ][cs_content_seo]Project PDF\n\n[/cs_content_seo][cs_element_social _id=”20″ ][cs_element_social _id=”21″ ][cs_element_social _id=”22″ ][cs_element_social _id=”23″ ][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”24″ ][cs_element_layout_row _id=”25″ ][cs_element_layout_column _id=”26″ ][cs_element_text _id=”27″ ][cs_content_seo]Project\n\n[/cs_content_seo][cs_element_text _id=”28″ ][cs_content_seo]The project is a new self‐storage facility on W. Gandy Boulevard in Tampa, Hillsborough County. The structure is a 5‐story storage facility with associated parking and drive areas. The site consists of an approximate 0.62‐acre. The site is bounded to the north by trees and a creek, to the west & east by commercial property, and to the south by West Gandy Boulevard. Due to the presence of very loose soils at depths between 20 and 40 feet below grade within the borings along the western extent of the building, a pre‐construction Compaction Grout (CG) program was performed within this area. Additionally, the client chose to also use a ground improvement program of Vibro‐Replacement Stone Columns (VSC), which were used to improve the shallow overburden soils upon completion of the pre-construction grout program and provide an allowable net bearing capacity of 6,000 psf.\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”29″ ][cs_element_layout_row _id=”30″ ][cs_element_layout_column _id=”31″ ][cs_element_text _id=”32″ ][cs_content_seo]Challenge\n\n[/cs_content_seo][cs_element_text _id=”33″ ][cs_content_seo]• Overhead power lines• Limited access within the tight, roadside site requiring MOT• Limited movement around the site, due to neighboring commercial properties• Delicate installation techniques along the north creek\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”34″ ][cs_element_layout_row _id=”35″ ][cs_element_layout_column _id=”36″ ][cs_element_text _id=”37″ ][cs_content_seo]Solution\n\n[/cs_content_seo][cs_element_text _id=”38″ ][cs_content_seo]Helicon followed the Compaction Grout (CG) parameters, provided by the Geotechnical Engineer of Record, during the installation. Our crew installed (21) grout injection points to approximately 40‐45 feet. Helicon also worked alongside the general contractor & the geotechnical/structural design teams, to develop a site‐conscious Vibro‐Replacement design submittal. The VSC Program was designed to meet the design load criteria of 6,000 psf allowable. Helicon’s VSC crew worked approx. 10‐hour shifts for six days a week, in order to meet the client’s critical path schedule. Efficient planning & coordination was key to overcoming the challenges & limitations. (220) Vibro‐Replacement Stone Columns (VSC) were installed from site grade to depths ranging from 15‐ft to 25‐ft. Helicon collaborated with theGeotechnical Engineer of Record throughout the work and confirmed all recommended criteria were followed. The CG & VSC work was successfully completed in just (10) days and finished on‐time and within budget.\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”39″ ][cs_element_row _id=”40″ ][cs_element_column _id=”41″ ][cs_element_image _id=”42″ ][cs_element_image _id=”43″ ][cs_element_gap _id=”44″ ][/cs_element_column][cs_element_column _id=”45″ ][cs_element_image _id=”46″ ][cs_element_image _id=”47″ ][/cs_element_column][/cs_element_row][/cs_element_section][/cs_content]