Proudly serving all of Florida with offices in Tampa, Orlando, and Fort Myers

Vibro Stone Columns: Assisted Living Facility, Wesley Chapel, FL

i 3 Table of Contents

Warning Signs Before a Sinkhole Forms You Should Never Ignore

Sinkholes don’t always start with a big, dramatic collapse. In fact, they often give off quiet warning signs that most homeowners miss, until it’s too late. That’s why staying alert can make all the difference. Have you noticed unusual cracks in your driveway? Maybe...

Cracked Foundation Wall Repair Tips for Lasting Home Stability

Noticed a crack running along your foundation wall? It might seem like just a surface issue, but it could be a sign of something more serious. Foundation cracks, if left untreated, can impact your home’s structural integrity, safety, and long-term value. These cracks...

Signs of structural foundation failure to watch for in your home

Your home’s foundation is the backbone that holds everything together. When it starts to fail, the signs can be subtle—or sometimes glaringly obvious. Noticing these warning signals early can save you from costly repairs and keep your family safe. Have you seen cracks...

New Pool Foundation Support Tips for a Strong and Lasting Build

Building a new pool is an exciting project, but have you thought about what’s beneath the surface? Your pool’s foundation plays a crucial role in ensuring that your backyard oasis stays beautiful, safe, and durable for years to come. In places like Florida, where soil...

Contact us anytime!

[cs_content][cs_element_section _id=”1″ ][cs_element_row _id=”2″ ][cs_element_column _id=”3″ ][cs_element_headline _id=”4″ ][cs_content_seo]Blue Heron Health & Rehab Project\n\n[/cs_content_seo][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”5″ ][cs_element_row _id=”6″ ][cs_element_column _id=”7″ ][cs_element_video _id=”8″ ][cs_element_gap _id=”9″ ][/cs_element_column][cs_element_column _id=”10″ ][cs_element_headline _id=”11″ ][cs_content_seo]Wesley Chapel, FL\n\n[/cs_content_seo][cs_element_gap _id=”12″ ][cs_element_text _id=”13″ ][cs_content_seo]CLIENT: The Douglas Company
ENGINEER: Mortensen Engineering
MARKET: Institutional
SOLUTION: Ground Improvement
SERVICES: Compaction Grout, Vibro \n\n[/cs_content_seo][cs_element_gap _id=”14″ ][cs_element_headline _id=”15″ ][cs_content_seo]Ground improvement for a 57,600 square-foot building\n\n[/cs_content_seo][cs_element_headline _id=”16″ ][cs_content_seo]21 Compaction Grout Injection Points\n\n[/cs_content_seo][cs_element_headline _id=”17″ ][cs_content_seo]394 Vibro-Replacement Stone Columns\n\n[/cs_content_seo][cs_element_gap _id=”18″ ][cs_element_button _id=”19″ ][cs_content_seo]Project PDF\n\n[/cs_content_seo][cs_element_social _id=”20″ ][cs_element_social _id=”21″ ][cs_element_social _id=”22″ ][cs_element_social _id=”23″ ][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”24″ ][cs_element_layout_row _id=”25″ ][cs_element_layout_column _id=”26″ ][cs_element_text _id=”27″ ][cs_content_seo]Project\n\n[/cs_content_seo][cs_element_text _id=”28″ ][cs_content_seo]The project is a new Health & Rehabilitation facility in the Seven Oaks Community, located in Wesley Chapel, Pasco County. The structure is approximately 57,600 square‐foot building with associated roadway, pavement & parking areas. Due to the presence of loose to medium‐dense fine sands to slightly clayey fine sands in the upper 25 feet, the Geotechnical Engineer of Record recommended a ground improvement program for Vibro‐Replacement Stone Columns (VSC). In addition, because of the presence of overburden soil erosion/raveling evidence related to possible “sinkhole conditions”, the Geotechnical EOR recommended a Compaction Grouting (CG) program to mitigate the concerns.\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”29″ ][cs_element_layout_row _id=”30″ ][cs_element_layout_column _id=”31″ ][cs_element_text _id=”32″ ][cs_content_seo]Challenge\n\n[/cs_content_seo][cs_element_text _id=”33″ ][cs_content_seo]The challenges encountered during VSC installation were minimal:• Limited movement around the site, due to ongoing site conditions• Weather conditions were unfavorable and slowed production\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”34″ ][cs_element_layout_row _id=”35″ ][cs_element_layout_column _id=”36″ ][cs_element_text _id=”37″ ][cs_content_seo]Solution\n\n[/cs_content_seo][cs_element_text _id=”38″ ][cs_content_seo]Helicon followed the Compaction Grout (CG) parameters, provided by the Geotechnical Engineer of Record, during the installation. Our crew installed (21) grout injection points to approximately 30‐50 feet. Helicon also worked alongside the general contractor & the geotechnical/structural design teams, to develop a cost‐conscious Vibro‐Replacement design submittal. The VSC Program was designed to meet the design load criteria of 6,000 psf allowable. Helicon’s VSC crew worked approx. 10‐hour shifts for up to six days a week, in order to meet the client’s critical path schedule. Efficient planning & coordination was key to overcoming the challenges & limitations. (394) Vibro‐Replacement Stone Columns (VSC) were installed from site grade to depths ranging from 10‐ft to 25‐ft. Helicon collaborated with the Geotechnical Engineer of Record throughout the work and confirmed all recommended criteria werefollowed. The CG & VSC work was successfully completed in just (12) days and finished on‐time and within budget.\n\n[/cs_content_seo][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”39″ ][cs_element_row _id=”40″ ][cs_element_column _id=”41″ ][cs_element_image _id=”42″ ][cs_element_image _id=”43″ ][cs_element_gap _id=”44″ ][/cs_element_column][cs_element_column _id=”45″ ][cs_element_image _id=”46″ ][cs_element_image _id=”47″ ][/cs_element_column][/cs_element_row][/cs_element_section][/cs_content]