[cs_content][cs_element_section _id=”1″ ][cs_element_row _id=”2″ ][cs_element_column _id=”3″ ][cs_element_headline _id=”4″ ][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”5″ ][cs_element_row _id=”6″ ][cs_element_column _id=”7″ ][cs_element_image _id=”8″ ][/cs_element_column][cs_element_column _id=”9″ ][cs_element_headline _id=”10″ ][cs_element_gap _id=”11″ ][cs_element_text _id=”12″ ][cs_element_gap _id=”13″ ][cs_element_headline _id=”14″ ][cs_element_headline _id=”15″ ][cs_element_headline _id=”16″ ][cs_element_headline _id=”17″ ][cs_element_gap _id=”18″ ][cs_element_button _id=”19″ ][cs_element_social _id=”20″ ][cs_element_social _id=”21″ ][cs_element_social _id=”22″ ][cs_element_social _id=”23″ ][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”24″ ][cs_element_layout_row _id=”25″ ][cs_element_layout_column _id=”26″ ][cs_element_text _id=”27″ ][cs_element_text _id=”28″ ][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”29″ ][cs_element_layout_row _id=”30″ ][cs_element_layout_column _id=”31″ ][cs_element_text _id=”32″ ][cs_element_text _id=”33″ ][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”34″ ][cs_element_layout_row _id=”35″ ][cs_element_layout_column _id=”36″ ][cs_element_text _id=”37″ ][cs_element_text _id=”38″ ][/cs_element_layout_column][/cs_element_layout_row][/cs_element_section][cs_element_section _id=”39″ ][cs_element_row _id=”40″ ][cs_element_column _id=”41″ ][cs_element_image _id=”42″ ][cs_element_image _id=”43″ ][cs_element_gap _id=”44″ ][/cs_element_column][cs_element_column _id=”45″ ][cs_element_image _id=”46″ ][cs_element_image _id=”47″ ][cs_element_gap _id=”48″ ][/cs_element_column][/cs_element_row][/cs_element_section][/cs_content][cs_content_seo]Go Mobile Flooring
Tampa, FL
CLIENT: Matcon Construction
MARKET: Commercial
SOLUTION: Deep Foundation
SERVICE: Helical Piers
Deep Foundation for a Retail Building
Installed (51) 12”x14”x14” triple helix design, 7”x7”x1/2” top plate
Total footage installed 1389
Avg Termination foot lbs of torque 7,000. with depth ranging from 20-50ft
Project PDF
Project
The project is a commercial retail building. The Geotechnical Engineer of Record recommended a deep foundation solution of helical piers to improve prove the load bearing capacity of the existing soils at the site.
Challenge
• Sandy/Silty soil conditions
Solution
Helicon worked alongside the geotechnical design team to develop a helical pier program designed to meet the building code load criteria. Helical Piers were installed to allow the General Contractor to utilize standard shallow footing construction, saving considerable time and cost. Helical piles require zero time after installation to load vs Auger Cast Piles, Micro Piles and they are more economical. Efficient planning & coordination was key to overcoming the challenges & limitations. Helicon collaborated with the Geotechnical Engineer of Record throughout the work and confirmed all recommended criteria were followed.